Error in ENE fARM 01F0: Floor heating is not allowed during protection operation

2016/12/14

Index

If floor heating is used during protection operation, Ene Farm will not return
I have located the cause in the instruction manual of Enefarm!
Six hours later, Ene Farm safely came back!
Do not use floor heating when Ene Farm is in protective operation


If floor heating is used during protection operation, Ene Farm will not return

I built a new building in August 2015 and attached Ene farm with sunlight.
The composition of sunlight and Enefarm is like this

In the meantime, Ene Farm has a bad timing, from morning Protective operation in progress (12 hours operation stopped)

If it is anticipated, Enefarm will not start up for about 8 hours.
Because it was cold, floor heating was on as usual.
But, something caught something in the mind (^ ^;)

Then in the evening ... When you look at the monitor of sudden farm, an error you have not seen has been displayed blinking with a chic! (; ゚ Д ゚)

"Error: 01F0"

This number like hexadecimal. What's this? ! No way, it was not broken in a year.
For the time being, I tried searching on the net, but something like that does not hit.

↓ I tried dropping the power supply, but just like an error, only the error is displayed as shimmer.


I have located the cause in the instruction manual of Enefarm!

Surely there should have been an instruction manual of Enefarm on the shelf! ···
was! And when I looked it up, it was on "01F0".

P98
"Other display: 01F0"

"Cause: Hot water supply and floor heating were used for a long time during the check of the microcomputer meter function (P.44)"

"Treatment: After refraining from using your gas equipment for one hour, turn off the hot water supply / bath switch, turn it on again after the screen disappears.
If the display does not disappear, please refrain from using the gas appliances for an hour or more before doing the same operation. "

···I see. .
Ene farm uses gas little by little. "Ene farm protection operation in progress"
"When I was not using Enefarm, it was to see if the gas was stopped properly".
At that time, using the gas little by little When you are turning on the floor heating, the microcomputer meter (probably the gas meter)
Can not check whether the gas is stopped · · · (; ^ ω ^)
Convinced. .

Six hours later, Ene Farm safely came back!

At about 4 p.m., I first stopped the floor warming and saw an hour. And as it was in the instruction manual,
From the remote control of Enefarm, press the "OFF / ON" button once to put it in "OFF" state, then I tried it again, but the error did not disappear.

Well, was it a bit too early? Next time I waited for 3 hours. It's around 8 o'clock in the evening. Switch off and put it ...
, But the error does not disappear (- -;)

Is it necessary to stop it for a longer time? ! In order to wait even further, try not to use the gas as much as possible, At around 10 p.m., I slowly switched off and put it in ...
Then! Finally! The error disappeared! ! (^ - ^)


Do not use floor heating when Ene Farm is in protective operation

After all, I spent an uneasy time about whether Enefarm will properly return for about 6 hours (^ ^;)

Even in winter, when Enefarm is under protective operation, you should not use floor heating.

This is like an iron rule. This is what you should do in the explanation when installing Enefarm ... (· _ · ;;
Everyone also think that it is better to let the floor warm be cut off when Enefarm is in protective operation.

In winter it was a terrible story of error "01F0" (◎ _ ◎;)